Test Cell 1

  • 5.2 MW, 3600 rpm Motor/Dyno with Variable Frequency Drive
  • Gearbox with interchangeable gear sets
    • 11,000 rpm max, 5200 ft-lb torque (7000 Nm)
    • 22,000 rpm max, 2950 ft-lb torque (4000 Nm)
    • Additional gear sets can be acquired for other torque/speed requirements
  • Independent data acquisition and control system
  • Connections to air plant hot and cold header available as needed
  • Cell mass flow capability
    • 50 lbm/sec, 24 kg/sec
    • Higher mass flow possible depending on installation
    • Atmospheric inlet condition available dependent on installation
  • Calibrated flow measurement systems
  • Inlet temperature: 1200° F max (650° C)
  • Exit temperature: 450° F max (230° C)
  • Inlet total pressure: 180 psia max (1240 kPA)
  • Secondary flow system
    • Up to 17 circuits
    • Individual flow controls and measurements
    • Reconfigurable and relocatable to other cells
  • Multiple lubrication systems available
  • Fast acting valve for surge control